Beam Deflection
calculator.
Find how far a beam sags under load, and the size, load or span that meets a limit.
- Against L/360
- Within
- Bending moment
- 4 kN·m
- Span ÷ deflection
- 8,000
The beam uses 4.5% of the L/360 allowance. This is a stiffness check only, not a strength or code approval.
Section, material and limit
The beam, exaggerated
Drag the far end to change the spanSimply supported beam 4 m long with a uniform load of 2 kN/m. It sags 0.5 mm at most, drawn exaggerated, against 11.1 mm allowed at L/360.
Working
- 1Second moment of area of a rectangleI =bh³12= 6.67 × 10⁻⁵ m⁴
- 2Deflection, simply supported, uniform loadδ =5wL⁴384EIwith w = 2,000 N/m, L = 4 m, E = 200 GPa, so δ = 0.5 mm
- 3Maximum bending momentM =wL²8= 4 kN·m
- 4Bending stress at the outer edgeσ =McI= 6 MPa
- 5Compare with L/360allowed =4 m360= 11.1 mm, so it is within the limit
- 6Check: the same deflection from the momentδ =5ML²48EI= 0.5 mm
Deflection at other spans
| Span | Deflection | L ÷ δ | L/360 |
|---|---|---|---|
| 3 m | 0.158 mmL/19,000 | 18,960 | Within |
| 3.6 m | 0.328 mmL/11,000 | 10,970 | Within |
| 4 m (yours) | 0.5 mmL/8,000 | 8,000 | Within |
| 4.4 m | 0.732 mmL/6,010 | 6,011 | Within |
| 5 m | 1.22 mmL/4,100 | 4,096 | Within |
Self-weight is not included. Add it to the uniform load if it matters for your beam.
How it's worked out
Each support and load pattern has its own closed formula from beam theory. The six here are the standard cases, as printed in the American Wood Council's beam formula sheets. For a simply supported beam under a uniform load:
w is the load per unit length, L the span, E the material's stiffness (Young's modulus) and I the second moment of area of the section, which measures how far its material sits from the bending axis. For a rectangle b wide and h deep:
A point load at midspan gives PL³ over 48EI. A cantilever with a load on its end gives PL³ over 3EI, 16 times as much for the same span, because nothing holds up the free end. Fixing both ends of a uniformly loaded beam cuts the sag to 20% of the simply supported figure.
The limit comes from IBC Table 1604.3: span over 360 for floor members under live load, over 240 for floors under total load and roofs over ordinary ceilings, and over 180 for roofs with no ceiling. Footnote i of that table checks a cantilever at twice its length. The bending stress is the moment times the distance to the outer edge, divided by I.
Worked examples
Jordan checks a 2×10 floor joist
A 2×10 is 1.5 by 9.25 inches. Jordan's spans 12 ft and carries 53 lb per foot, close to 40 lb per square foot over joists 16 inches apart. In Douglas fir-larch No. 2 it sags 0.157 in, span over 919.
L/360 on 12 ft allows 0.4 in, so the joist uses 39% of it. The same joist would reach the limit at a span of 16.4 ft. A 2×8 stretched to 14 ft sags 0.603 in against 0.467 in, which is over.
Ana turns a steel bar on its side
A solid steel section 100 mm wide and 200 mm deep, spanning 4 m under 2 kN per meter, sags 0.5 mm, span over 8,000. It uses 4.5% of the L/360 allowance.
Laid flat, 200 wide and 100 deep, it sags 2 mm, 4 times as much, because I grows with the cube of the depth but only in step with the width. Fixing both ends instead brings the upright section down to 0.1 mm.
Lee sizes an aluminum shelf bracket
A 40 by 10 mm aluminum bar sticks out 30 cm with 200 N on its end. It sags 7.84 mm at the tip. Checked as the code checks a cantilever, at twice its length, L/180 allows 3.33 mm, so it is over.
At that size the bracket meets the limit with about 85 N on the end. A bar 15 mm deep instead sags 2.32 mm under the full 200 N.
Reading your result
Deflection is a comfort and finish check, not a strength check. A floor that sags L/360 or less feels firm and keeps plaster from cracking, but the beam can still be overstressed, buckle sideways or fail at a connection. Compare the stress with the material's allowable value under your design code, or ask an engineer.
Span matters most. Under a uniform load the sag grows with the fourth power of the span. Making Ana's beam 10% longer, 4.4 m, raises the sag from 0.5 mm to 0.732 mm.
The wood moduli are rounded. Douglas fir-larch No. 2 is held as 11.0 GPa, the NDS Supplement value of 1,600,000 psi rounded to three figures, so its sag reads about 0.3% high. Spruce-pine-fir No. 2 is held as 9.65 GPa for the NDS 1,400,000 psi.
The reverse answers each change one input and keep the rest. The required I tells you how much stiffer a section must be; the largest load and the longest span tell you how much room you have.
Common mistakes
- Using nominal lumber sizes. A 2×10 is 1.5 by 9.25 inches, and the cube of the depth makes the difference large.
- Leaving out the beam's own weight. It is not included. Add it to the uniform load for long or heavy members.
- Mixing units for I. 1 in⁴ is 41.6 cm⁴, so pick the unit the table uses.
- Reading a point load as a uniform one. A load at midspan sags a simply supported beam 1.6 times as much as the same total spread along it.
Questions people ask
Sources
- American Wood Council, DA6 Beam Design Formulas with Shear and Moment Diagrams
- International Code Council, 2016 California Building Code errata, Table 1604.3 Deflection Limits
- American Wood Council, NDS 2018 Supplement, Chapter 4 Table 4A
- LibreTexts Engineering, Strength of Materials appendix: Material Properties
- Aerospace Metals, Titanium Ti-6Al-4V Grade 5 ELI annealed data sheet
- NIST Guide to the SI, Appendix B.8