Battery Life
calculator.
Estimate how long a battery runs a device, or the capacity you need for a runtime.
- Average current
- 250 mA
- Average power
- 0.925 W
- Rated energy
- 11.1 Wh
Halving the load doubles this runtime, because the charge used is current times time.
Battery type and load pattern
Set the active time under 100% to add an idle or sleep current.
Runtime by load
Drag the point to change the loadRuntime against the active load in mA. At your 250 mA it is 10 h 48 min; at half the load it is 21 h 36 min.
Working
- 1Usable capacity: rating times the usable share3 Ah × 90% = 2.7 Ah
- 2Runtime: usable charge divided by current2.7 Ah ÷ 0.25 A = 10.8 h
- 3Check: size a battery for this runtime10.8 h at 250 mA needs 3 Ah rated, the battery entered
Runtime at other loads
| Active load | Average | Runtime |
|---|---|---|
| 125 mA125 mA average | 125 mA | 21 h 36 min |
| 187.5 mA187.5 mA average | 187.5 mA | 14 h 24 min |
| 250 mA (yours)250 mA average | 250 mA | 10 h 48 min |
| 312.5 mA312.5 mA average | 312.5 mA | 8 h 38 min |
| 375 mA375 mA average | 375 mA | 7 h 12 min |
| 500 mA500 mA average | 500 mA | 5 h 24 min |
Taking it on a plane
Rated energy: 3.7 V × 3 Ah = 11.1 Wh.
From 49 CFR 175.10(a)(18), for lithium-ion cells. Airlines can set tighter limits.
How it's worked out
A battery rating in mAh or Ah is a store of charge. Charge used is current times time, so the runtime is the charge you plan to use divided by the average current.
C is the rated capacity in amp-hours, u the usable share, and I avg the average current in amps. A rating in watt-hours is divided by the battery voltage first, and so is a load in watts.
A device that sleeps spends most of its time at a tiny idle current. Its average is the active current weighted by the share of time it is awake, plus the idle current for the rest.
Lead-acid batteries give less than their label at high currents. Peukert's law corrects for that, with H the hours the rating was measured over (usually 20) and k the Peukert exponent. The Victron battery monitor manual uses 1.25 as its default for lead-acid, and the tool does too. Lithium cells are treated as k = 1.
Sizing runs the same law backwards: it solves for the usable charge that lasts your runtime, then divides by the usable share to get the rating to buy.
Worked examples
Maya checks a phone-size cell at 250 mA
Maya plans to use 90% of a 3,000 mAh lithium-ion cell, which is 2,700 mAh. At a steady 250 mA that lasts 10.8 hours, or 10 h 48 min.
The cell stores 11.1 Wh at its rating. Her board draws 0.925 W on average, so the usable 9.99 Wh gives the same runtime by the energy route.
Theo runs a sensor on a coin cell
Theo's sensor draws 20 mA while it measures and sends, which is 1% of the time, and 10 µA asleep. Its average is 0.2099 mA, so a 220 mAh coin cell at 90% usable lasts about 39.3 days.
Left awake, the same cell would last only 9 h 54 min. Cutting the awake time to 0.5% stretches it to 75 days, because the active share is still most of the average.
Sam runs a cool box from a lead-acid battery
A 120 W cool box on a 12 V battery draws 10 A. Sam only takes the 100 Ah battery down to half, so a plain division says 5 h.
With Peukert's law at k = 1.25 the estimate falls to 3 h 32 min, because 10 A drains it far faster than the 20 hours its rating was measured over. For a full 8 hour night at that load he would need about 192 Ah rated, not the 160 Ah a plain sum gives.
Reading your result
The runtime is a planning figure. Cold, age and a drained cell sagging below the device's cutoff all cut it. Battery University advises designing for a pack that has faded to 70 to 80% of its rating, which is what the usable share is for.
Average current is the number to check first. If it comes out far above what you expected, look for a radio or a display that stays on. A USB power meter or a meter in series shows the real draw.
Rated energy decides the airline question. US rules in 49 CFR 175.10 allow lithium-ion batteries up to 100 Wh, and over 100 up to 160 Wh with the airline's approval, with spares in carry-on bags only. A 10,000 mAh bank at 3.7 V is 37 Wh, well inside.
Common mistakes
- Comparing mAh across voltages. A 12 V battery and a 3.7 V cell with the same mAh hold very different energy. Compare watt-hours instead.
- Using the peak current as the load. Radios draw short bursts many times the average. Use the average over a full cycle, or set the active time.
- Expecting a power bank's label at its USB port. The rating is for its 3.7 V cells, and the boost to 5 V loses some energy on the way.