Nernst Equation
calculator.
Work out a cell voltage at real concentrations and temperatures, not just under standard ones.
- ΔG = −nFE (kJ/mol)
- −224.4
- Equilibrium constant K
- 10^37.31
- Per tenfold Q
- 29.58 mV
Each tenfold rise in Q takes 29.58 mV off this cell at 25 °C. Q is still below K (10^37.31), so the reaction runs forward.
Cell potential against log₁₀ Q
Drag the point to move QA straight line falling 29.58 mV for each tenfold rise in Q. You are at log₁₀ Q = −2 and E = 1.1629 V. It crosses 0 V where Q equals K, at log₁₀ Q = 37.313, outside this view.
At other values of Q
| Q | E (V) | ΔG (kJ/mol) |
|---|---|---|
| 10^−8 | 1.3403 | −258.6 |
| 10^−6 | 1.2812 | −247.2 |
| 10^−4 | 1.222 | −235.8 |
| 0.01 | 1.1629 | −224.4 |
| 1 | 1.1037 | −213 |
| 100 | 1.0445 | −201.6 |
| 10^4 | 0.98538 | −190.1 |
Build E° from two half-reactions
E° = 0.3419 − (−0.7618) = 1.1037 V at 25 °C, with n = 2. Choosing a pair fills E° and n above.
Working
- 1Nernst equationE=E°−RTnFln Q
- 2The temperature term, with T in kelvin8.314462618 × 298.152 × 96,485.33212= 0.012846 V
- 3Put the numbers inE = 1.1037 − 0.012846 × ln 0.01 = 1.1629 V
- 4Check: the Q this voltage impliesexp((1.1037 − 1.1629) ÷ 0.012846) = 0.01
How it's worked out
A table of standard potentials, E°, assumes every ion is at 1 M and the cell sits at 25 °C. Real cells rarely do. The Nernst equation corrects E° for the mix you actually have.
Here R is the gas constant, T the temperature in kelvin, n the electrons passed in the balanced reaction, and F the Faraday constant, the charge on a mole of electrons. Q, the reaction quotient, is products over reactants, with solids left out. The tool uses the exact 2018 values from NIST for R and F.
At 25 °C that factor is 59.16 mV, the 0.0592 V you see in many textbooks, which then use log₁₀ Q in place of ln Q. At body temperature it rises to 61.54 mV. So the shortcut with 0.0592 holds only at 25 °C, while this tool keeps the full form for any temperature.
The same E° fixes ΔG and K. ΔG = −nFE gives the free energy change, and E reaches 0 when Q equals K. For the zinc and copper cell, log₁₀ K is about 37.31, a number far too large to write out.
Worked examples
Jonah tests a fresh Daniell cell
Jonah sets up zinc in 0.01 M Zn²⁺ and copper in 1 M Cu²⁺. E° is the cathode minus the anode, 0.3419 − (−0.7618), or 1.1037 V. Two electrons move, and Q is the zinc ion over the copper ion, 0.01.
A small Q pushes E above E°. As the cell runs, zinc ions build up and copper ions run out. At Q = 100 the same cell gives 1.0445 V. ΔG at Q = 0.01 is −224.4 kJ per mole of reaction, so it runs on its own.
Ruth finds the potassium potential of a neuron
A nerve cell holds about 140 mM potassium inside and 5 mM outside. The same ion sits on both sides, so E° is 0 and the voltage comes only from the 28 to 1 ratio. With n = 1 at 37 °C, the result is 89.06 mV.
Physiologists quote it as negative, inside against outside, because positive potassium ions leave and the inside is left negative. The size is the same.
Ali reads 1.15 V and works back to Q
Ali's voltmeter shows 1.15 V on a zinc and copper cell, above its E° of 1.1037 V. A voltage above E° means Q is below 1, so the zinc ion is the more dilute of the two. Running the equation backward gives Q = 0.0272.
This is the idea behind ion-selective electrodes: a measured voltage tells you a concentration ratio.
Reading your result
A positive E means the reaction runs forward on its own, as a battery. A negative E means it needs an outside voltage, as in electroplating. Zero means the cell has reached equilibrium and can do no more work.
Tenfold steps. Each tenfold rise in Q takes 29.6 mV off a two-electron cell at 25 °C. That is why a battery's voltage holds fairly steady for most of its life and then falls once one ion nearly runs out.
Concentration cells need no difference in metal at all. OpenStax's zinc cell with 0.50 M and 0.10 M gives 20.7 mV, and copper at 1 M against 1 mM gives 88.7 mV.
Temperature changes only the RT term. At 50 °C the fresh Daniell cell above gives 1.1678 V, slightly more than at 25 °C, because Q is below 1. With Q above 1, warming lowers E instead, and at Q = 1 it does nothing.
Common mistakes
- Using 0.0592 at another temperature. The 0.0592 V form is the 25 °C value. Enter the real temperature instead.
- Writing Q upside down. Q is products over reactants. For the zinc and copper cell it is [Zn²⁺] over [Cu²⁺], not the reverse.
- Picking the wrong n. n counts the electrons in the balanced cell reaction. Silver with zinc moves 2, even though each silver ion takes 1.
- Multiplying E° by a coefficient. Doubling a half-reaction does not double its E°. Only n and Q change.
- Using Celsius for T. The equation needs kelvin. The tool converts °C and °F for you.