Arrhenius Equation
calculator.
Reaction rates climb with temperature; activation energy sets how steeply they do.
- Speeds up by
- × 1.924
- Same progress takes
- × 0.5197
At 35 °C this reaction runs 1.92 times faster than at 25 °C, so the same progress takes 0.52 times as long.
From 25 °C, this is 1.924 times the rate.
Rate against temperature
Drag the point to change the temperatureThe rate climbs faster and faster as it warms. At 25 °C it is 1 by definition, and at 35 °C it is 1.924 times that.
Arrhenius plot
Across: 1000 ÷ T in kelvins. Up: ln kThe line falls by 6.014 for each 1 you move to the right. That slope is Ea over R, in thousands of kelvins.
Rate at nearby temperatures
| T (°C) | k | Multiple |
|---|---|---|
| −5 | 0.1047 | × 0.1047 |
| 5 | 0.2345 | × 0.2345 |
| 15 | 0.4966 | × 0.4966 |
| 25 | 1 | × 1 |
| 35 | 1.924 | × 1.924 |
| 45 | 3.554 | × 3.554 |
| 55 | 6.321 | × 6.321 |
| 75 | 18.11 | × 18.11 |
Working
- 1Two-point form: A cancels when you divide one rate by the otherk₂ = k₁ × ex, with x =EaR(1T₁−1T₂)
- 2Put temperatures in kelvins and Ea in J/molT₁ = 298.15 K, T₂ = 308.15 K, Ea = 50,000 J/mol
- 3Work out the exponentx =50,0008.314463(1298.15−1308.15) = 0.65454
- 4Raise e to that power and multiply by k₁k₂ = 1 × e0.65454 = 1.9243
- 5Check: k₁ and k₂ give the same Ea backEa =8.314463 × ln(1.9243 ÷ 1)1 ÷ 298.15 − 1 ÷ 308.15= 50,000 J/mol
How it's worked out
Molecules must collide with enough energy to rearrange their bonds. That minimum is the activation energy, written Ea. OpenStax gives the link between rate and temperature as a single equation.
Here k is the rate constant and T is the temperature in kelvins. A is the frequency factor, which reflects how often molecules collide and how well they line up. R is the molar gas constant, 8.314462618 J/(mol·K) in the NIST listing. The tool always turns Ea into J/mol and T into kelvins before it starts, so the units cancel whichever ones you enter.
Divide the equation at one temperature by the same equation at another, and A cancels. That is why two measurements are enough to find Ea, and why you can predict a new k without knowing A at all.
Take logs of the first equation and you get a straight line. Plot ln k against 1 over T, and the slope is minus Ea over R, while the intercept is ln A. A class that asks for "the graphical method" wants that line, and the plot here draws it through your points.
Worked examples
Marta finds Ea from two textbook rate constants
Her problem set gives 1.66 L/mol/s at 650 K and 7.39 L/mol/s at 700 K. The two-point form returns 113 kJ/mol. OpenStax gives 1.1 × 10⁵ J/mol for the same data, which is this figure rounded to two digits.
The frequency factor comes out near 2 × 10⁹, in the same L/mol/s as k. Over the first 10 degrees above 650 K the rate rises only 1.37 times, far short of doubling, because a 10 degree step matters less at a high temperature.
Jon compares food on the counter and in the fridge
Jon assumes a spoilage reaction with a barrier of 80 kJ/mol, then sets k₁ to 1 so that k₂ reads as a multiple. Going from 22 °C to 4 °C gives 0.12, so the reaction runs 8.31 times slower.
That means the same chemical change takes about 8.31 times as long. It is a sum about one reaction with an assumed Ea, not a shelf life: real spoilage involves microbes and many reactions at once.
Wei gets k and a half-life from table values
A table lists A = 10¹³ s⁻¹ and Ea = 100 kJ/mol for a first-order reaction. At 25 °C the exponential term is 3 × 10⁻¹⁸, so k is 3 × 10⁻⁵ s⁻¹.
For a first-order reaction the half-life is ln 2 over k, here 6.36 hours. That step needs k per second. A second-order k has other units, and its half-life also depends on concentration, so the tool's figure does not apply to it.
Reading your result
Bigger barrier, stronger reaction to heat. Over the same 25 °C to 35 °C step, the rate change depends on Ea alone.
| Ea (kJ/mol) | Multiple |
|---|---|
| 25 | × 1.39 |
| 50 | × 1.92 |
| 75 | × 2.67 |
| 100 | × 3.7 |
| 150 | × 7.13 |
The doubling rule is a rough guide. Stephen Lower's notes/Kinetics/06%3A_Modeling_Reaction_Kinetics/6.02%3A_Temperature_Dependence_of_Reaction_Rates/6.2.03%3A_The_Arrhenius_Law/6.2.3.01%3A_Arrhenius_Equation) say a ten degree rise approximately doubles a rate, then warn that this is not generally true. To double over 295 K to 305 K, a reaction needs 51.9 kJ/mol. A 100 kJ/mol reaction goes up 3.7 times over 25 °C to 35 °C.
The doubling temperature is more useful. A 50 kJ/mol reaction at 298.15 K doubles at 308.76 K, a rise of about 10.6 degrees. The tool shows this figure for your barrier, along with the temperature that halves the rate.
Read the exponential term with care. Lower describes it as the fraction of molecules with enough energy to react. For 50 kJ/mol at 25 °C it is 1.7 × 10⁻⁹, so a modest barrier cuts the rate by a factor of many million against A. The figure should stay between 0 and 1.
Common mistakes
- Using Celsius in the equation. T must be in kelvins, and so must both temperatures in the two-point form. Plugging in 25 and 35 gives an Ea that is far too small. The boxes here take °C, K or °F and convert first.
- Mixing kJ and J. R is in joules, so 50 kJ/mol has to go in as 50,000 J/mol. Forgetting that changes the exponent by a factor of 1,000.
- Reversing the two points. Swap T₁ and T₂ without swapping k₁ and k₂, and Ea turns negative. A negative result from clean data usually means this, not exotic chemistry.
- Extrapolating too far. A stability test at 60 °C with an assumed 80 kJ/mol reads as 29.7 times faster than 25 °C. That only holds if the same reaction controls the rate at both temperatures, and a different step or a denatured enzyme breaks the straight line.