Weibull Distribution
calculator.
The Weibull distribution models when parts fail, from early defects to wear-out.
- Hazard, per hour
- 0.00016001.6 × 10⁻⁴
- Mean life (hours)
- 8,862.269
- B10 life (hours)
- 3,245.928
With k above 1, the failure rate rises with age, the pattern of wear-out. A unit this old has a 84.366% chance of lasting 1,000 more hours, below a new unit's 99.005%.
When failures happen
Drag the point to change the ageFailure density for k = 2 and λ = 10000. The shaded area up to age 8000 is 47.271%, the share failed by then. The mean life is 8,862.269 hours and the median is 8,325.546 hours.
After this age
Location is a failure-free period before any unit can fail. Leave it at 0 unless you have a physical reason for one.
- Chance a unit this old lasts the mission
- 84.366%
- Chance a new unit lasts the mission
- 99.005%
- Expected further life (hours)
- 4,334.541
Find an age from a failure percent
- B10 life (hours)
- 3,245.928
- Reliability at that age
- 90%
Shape and scale from two known points
- Shape k
- 1.9999
- Scale λ
- 10,000.6084
Reliability and failed share
Reliability falls from 100% as the failed share rises toward 100%. At age 8000, reliability is 52.729% and the failed share is 47.271%. The two curves cross at the median, 8,325.546 hours.
Hazard rate
With k above 1, the failure rate rises with age, the pattern of wear-out. At age 8000 the hazard is 0.0001600 per hour.
Working
- 1Divide the age by the scale8,00010,000= 0.8
- 2Raise that to the shape, for the cumulative hazard0.82 = 0.64
- 3Reliability is e to the minus thatR = e−0.64 = 52.729%
- 4Hazard: shape over scale, times the scaled age to k − 1210,000× 0.81= 0.0001600 per hour
- 5Mean life: the scale times a gamma function10,000 × Γ(1 +12) = 8,862.269
- 6Check: put the reliability back and solve for the aget = 10,000 × (−ln R)1k = 8,000
The same scale at age 8,000, other shapes
| h(t) | Mean | |||
|---|---|---|---|---|
| 1h(t) 0.0001000 | 0.0001000 | 44.933%Mean 10,000 | 10,000 | 1,053.605 |
| 1.5h(t) 0.0001342 | 0.0001342 | 48.893%Mean 9,027.453 | 9,027.453 | 2,230.755 |
| 2h(t) 0.0001600 | 0.0001600 | 52.729%Mean 8,862.269 | 8,862.269 | 3,245.928 |
| 2.5h(t) 0.0001789 | 0.0001789 | 56.415%Mean 8,872.638 | 8,872.638 | 4,065.099 |
| 3h(t) 0.0001920 | 0.0001920 | 59.93%Mean 8,929.795 | 8,929.795 | 4,723.087 |
At multiples of the scale
| Multiple of λ | R(t) | F(t) | h(t) | |
|---|---|---|---|---|
| 2,500Multiple of λ 0.25 | 0.25 | 93.941%h(t) 0.00005000 | 6.059% | 0.00005000 |
| 5,000Multiple of λ 0.5 | 0.5 | 77.88%h(t) 0.0001000 | 22.12% | 0.0001000 |
| 7,500Multiple of λ 0.75 | 0.75 | 56.978%h(t) 0.0001500 | 43.022% | 0.0001500 |
| 10,000Multiple of λ 1 | 1 | 36.788%h(t) 0.0002000 | 63.212% | 0.0002000 |
| 12,500Multiple of λ 1.25 | 1.25 | 20.961%h(t) 0.0002500 | 79.039% | 0.0002500 |
| 15,000Multiple of λ 1.5 | 1.5 | 10.54%h(t) 0.0003000 | 89.46% | 0.0003000 |
| 20,000Multiple of λ 2 | 2 | 1.832%h(t) 0.0004000 | 98.168% | 0.0004000 |
B-lives
| Life | Reliability | |
|---|---|---|
| B1 | 1,002.514 | 99% |
| B5 | 2,264.802 | 95% |
| B10 | 3,245.928 | 90% |
| B20 | 4,723.807 | 80% |
| B50 | 8,325.546 | 50% |
| B63.2 | 9,998.362 | 36.8% |
| B90 | 15,174.271 | 10% |
How it's worked out
Two numbers set the curve. The shape k, also written β, says how failures behave over time. The scale λ, also written η, stretches the curve along the age axis. NIST calls the scale the characteristic life. Reliability R(t) is the share still working at age t.
The share failed is F(t) = 1 − R(t). At t = λ the exponent is −1 for any shape, so about 36.8% are still working and 63.2% have failed. That is why the scale sits at the 63.2% point whatever the shape.
Density and hazard
The density f(t) shows when failures bunch up. The hazard h(t) is the failure rate among units that are still working, which is the density divided by the reliability.
Below k = 1 the hazard falls with age, which matches the early failure stretch of the bathtub curve. At k = 1 it stays flat and the model is the exponential distribution. Above 1 it rises, which is wear-out. At k = 2 NIST names it the Rayleigh distribution.
Mean, median and B-life
Γ is the gamma function. A B-life is the age by which a share p has failed, so B10 sets p to 0.10. The median is B50. The mode, the peak of the density, sits above zero only when k is above 1.
A unit that has already survived
The chance of lasting a further x, given it has reached t, is a ratio of two reliabilities. Its expected further life is the area under R past t, divided by R(t), which the tool works out with the incomplete gamma function.
A location γ shifts the whole curve so no failure can happen before age γ. NIST's general form replaces t with t − γ in each formula above.
Worked examples
A wearing part at 8,000 hours
A pump seal has k = 2 and λ = 10,000 hours. At 8,000 hours, R = 52.73%, so 47.27% of seals have failed. The hazard is 0.00016 per hour, the mean life is 8,862 hours, and B10 comes at 3,246 hours.
A new seal gets through 1,000 hours 99% of the time. A seal already at 8,000 hours manages it only 84.37% of the time, and it can expect about 4,335 more hours. That falling chance is what makes planned replacement worth it for wear-out.
Early failures, and why survivors look better
A batch of electronics has k = 0.5 and λ = 1,000 hours. A new unit gets through its first 200 hours 63.94% of the time. A unit that already survived 200 hours gets through the next 200 83.09% of the time, which is better than new.
This is the reasoning behind burn-in, which runs parts before service so the weak ones fail early. Replacing a survivor with a new unit makes things worse here. The mean life of 2,000 hours is far above the median of 480, because a few units last a very long time.
A fit from test data, with half the units still running
NIST's handbook works through 20 units: 10 failed within 386 hours, and 10 were still running when the test stopped at 500. Its maximum likelihood fit is k = 1.7208 and λ = 606.528. Here the engine's mean is 540.7 hours and its standard deviation is 323.8, which match NIST's published 540.7 and 323.8 to the decimal shown.
At 500 hours, the end of the test, R = 48.81%. That sits close to the 10 of 20 units seen running, as a fit should. The estimate of k carries real uncertainty with so few failures: at k = 1.29 the reliability would be 45.87%, and at k = 2.15 it would be 51.68%.
Reading your result
Start with the shape. It tells you whether age matters. With k = 1 and λ = 5,000 hours, a new unit lasts the next 1,000 hours 81.87% of the time, and one already at 8,000 hours gets 81.87%. Those match, so replacing a working unit early buys nothing. Above k = 1 that same trade starts to pay, and below it the trade loses.
Do not read the scale as the mean. The scale is a percentile, not an average. Accendo Reliability states that the two match only at k = 1 with no location. At k = 0.5 the mean is 2 times λ, and at k = 2 it is 0.886 times λ.
Read B-lives for the early part of the curve. A mean says little about the first failures, and those are often what a warranty or a safety case cares about. Rolling bearings use the same idea: L10 is the life that 90% of bearings reach or exceed.
| k | Mean | Median | Mode |
|---|---|---|---|
| 0.5 | 2 | 0.48 | 0 |
| 1 | 1 | 0.693 | 0 |
| 1.5 | 0.903 | 0.783 | 0.481 |
| 2 | 0.886 | 0.833 | 0.707 |
| 3.6 | 0.901 | 0.903 | 0.914 |
| 5 | 0.918 | 0.929 | 0.956 |
| k | SD | B10 | R at 0.5λ |
|---|---|---|---|
| 0.5 | 4.472 | 0.011 | 49.3% |
| 1 | 1 | 0.105 | 60.7% |
| 1.5 | 0.613 | 0.223 | 70.2% |
| 2 | 0.463 | 0.325 | 77.9% |
| 3.6 | 0.278 | 0.535 | 92.1% |
| 5 | 0.21 | 0.638 | 96.9% |
Small k spreads failures over a huge range, so B10 comes very early while the mean stays high. As k grows the curve tightens around λ. Near k = 3.6 the mean, median and mode almost meet, at 0.901, 0.903 and 0.914 times λ.
Common mistakes
- Treating the hazard as a probability. It is a rate per unit of age. It only approximates a chance of failure over a short stretch, and its size changes when you switch from hours to days. Use the mission figure for a real chance.
- Fitting one curve to two failure causes. A single Weibull describes one failure mode. A product with both early defects and wear-out needs one curve per mode, and a single fit will hide both.
- Adding a location without a reason. Use γ only when something physical rules out failure before that age. Setting it because it improves the fit to a small data set can make early-life figures look safer than they are.
- Dropping the units that have not failed. Leaving out units still running makes the life look shorter than it is. Fit methods such as maximum likelihood use them, and this tool works forward from k and λ once you have them.
Questions people ask
Sources
- NIST/SEMATECH e-Handbook, section 8.1.6.2, Weibull
- NIST/SEMATECH e-Handbook, section 1.3.6.6.8, Weibull Distribution
- NIST/SEMATECH e-Handbook, section 1.3.3.30, Weibull Plot
- NIST/SEMATECH e-Handbook, section 8.1.2.4, Bathtub Curve
- NIST/SEMATECH e-Handbook, section 8.4.1.3, A Weibull maximum likelihood estimation example
- Accendo Reliability, The 2-Parameter Weibull Distribution: 7 Formulas
- Accendo Reliability, B10 Life for Weibull and Lognormal Distributions
- Accendo Reliability, Calculate Weibull Mean and Variance
- Wikipedia, Rolling-element bearing
- Wikipedia, Burn-in