MathsPercentages

Percentage Error
calculator.

Find the error between your result and the accepted value, for a lab report.

How it's worked out

Take the accepted value away from your measurement, ignore the sign, divide by the size of the accepted value, and multiply by 100:

percentage error\displaystyle \text{percentage error}=|measured−accepted||accepted|×100\displaystyle {}= \frac{|\,\text{measured} - \text{accepted}\,|}{|\,\text{accepted}\,|} \times 100

The top line on its own is the absolute error. It keeps the unit of the measurement, such as m/s² or mol/L. The fraction before you multiply by 100 is the relative error, which has no unit. The accepted value sits on the bottom because it is the reference, so it cannot be zero.

The signed error keeps the direction. The international vocabulary of metrology (JCGM 200, the VIM) defines measurement error as the measured value minus the reference value, so a positive sign means your result is high:

signed error\displaystyle \text{signed error}=measured−accepted|accepted|×100\displaystyle {}= \frac{\text{measured} - \text{accepted}}{|\,\text{accepted}\,|} \times 100

With several trials, the tool averages them first and works out the error of the mean. It also gives each trial its own error and the sample standard deviation of the trials.

Worked examples

A pendulum measurement of g

Zara timed a pendulum and got g = 9.75 m/s². Standard gravity is exactly 9.80665 m/s². The error is 9.75 − 9.80665 = −0.05665 m/s², so the absolute error is 0.05665 m/s². Dividing by 9.80665 gives a relative error of 0.00578, and the percentage error is 0.578% to three significant figures. Her value is low, so the signed error is −0.578%.

Open this example in the tool

A titration against a standard

Ben titrated a solution made up to 0.1000 mol/L and found 0.0968 mol/L. The percentage error is 3.20%, low. His instructor allows 3%, which means any result from 0.097 to 0.103 mol/L passes, so this one just misses.

Open this example in the tool

Four trials of the same pendulum

Zara repeats the timing four times and gets 9.71, 9.84, 9.77, 9.8 m/s². The mean is 9.78 m/s², a percentage error of 0.272%. The spread of the trials (sample standard deviation) is 0.0548 m/s², which is larger than the mean's offset of 0.02665 m/s². The scatter between trials is the bigger problem, not a bias in the method.

Open this example in the tool

Reading your result

There is no cut-off that makes an error good or bad for every experiment. Compare it with the uncertainty of your instruments, or with the tolerance in your lab manual. Set that tolerance in the tool and it shows the range of readings that would pass, shaded on the chart.

Percentage error measures accuracy: how close you are to the accepted value. The spread of repeated trials measures precision: how close your trials are to each other. If the mean is off by more than the spread, look for a systematic cause, such as a timer started late or a scale that was not zeroed.

Round the error for your report, not along the way. Follow your course's rule for how many significant figures to give; the tool rounds to 2, 3 or 4, or shows every digit. It also tells you how many significant figures your measurement has, and the working uses the same rounding as the answer.

Common mistakes

  • Dividing by the measured value. The accepted value goes on the bottom. Dividing by your own result gives a different number.
  • Mixing up the sign. Some manuals write accepted minus measured, which flips the signed error. The unsigned percentage error is the same either way, so say which form you report.
  • Mixing units. Put both values in the same unit first. An error like 200% (3 measured against 1 accepted) usually means a unit slip or a misplaced decimal point.
  • Losing the size of a negative reference. Divide by the size of the accepted value. A reading of −9.5 against −10 is a 5.00% error.
  • Calling percentage error a percentage change. A change compares a new value with an old one. An error compares a result with a reference.

Questions people ask

Percent error is the absolute difference between the measured and accepted values, divided by the absolute accepted value, times 100. A measurement of 105 against an accepted 100 is |105 − 100| ÷ 100 × 100 = 5%.

Sources