IV Drip Rate
calculator.
This IV drip rate calculator turns an order into drops a minute or a pump rate.
Set the roller clamp to 42 drops a minute, about 10 every 15 seconds, to run 1,000 mL in 8 h at 125 mL/h. Counting a whole 42 drops delivers 126 mL/h, so a bag started at 8:00 a.m. ends at 3:56 p.m. instead of 4:00 p.m.
For checking your own arithmetic only. Follow the order, your pump's drug library and your facility's double-check policy.
The bag emptying
Drag the brass point to a check timeHours since the start run across and mL left in the bag up. The line falls by 125 mL each hour, from 1,000 mL to empty at 8 h (4:00 p.m.). At the brass point, 4 h in (12:00 p.m.), 500 mL has gone in and 500 mL is left.
Time strip for the bag
Expected level at each mark
| Time | In (mL) | Left (mL) |
|---|---|---|
| 8:00 a.m. | 0 | 1,000 |
| 9:00 a.m. | 125 | 875 |
| 10:00 a.m. | 250 | 750 |
| 11:00 a.m. | 375 | 625 |
| 12:00 p.m. | 500 | 500 |
| 1:00 p.m. | 625 | 375 |
Mark the levels on tape down the side of the bag. If the fluid is above or below a mark at that time, recount and adjust.
The same rate on other tubing
125 mL/h on each drop factor
| Tubing | Exact | Count | Gives |
|---|---|---|---|
| 10 gtt/mL | 20.8 | 21 | 126 |
| 15 gtt/mL | 31.3 | 31 | 124 |
| 20 gtt/mL (yours) | 41.7 | 42 | 126 |
| 60 gtt/mL | 125 | 125 | 125 |
"Gives" is the rate the whole-drop count delivers. The fewer drops per mL, the more each rounded drop changes the rate.
Working
- 1Change hours to minutes8 h × 60 = 480 min
- 2Drops a minute: volume × drop factor ÷ minutes1,000 mL × 20 gtt/mL ÷ 480 min = 41.7 gtt/min
- 3Round to a whole drop you can count41.7 rounds to 42 gtt/min
- 4Pump rate: volume ÷ hours1,000 mL ÷ 8 h = 125 mL/h
- 5Check: drops × minutes ÷ drop factor gives the volume back41.7 × 480 ÷ 20 ≈ 1,000 mL
How it's worked out
A gravity drip is set by counting drops in the drip chamber, so the order has to be turned into drops a minute. The tubing package tells you how many drops make one milliliter. That number is the drop factor.
V is the volume in mL, D the drop factor in drops per mL and t the time in minutes. Gtt is short for the Latin guttae, drops. Macrodrip sets give 10, 15 or 20 drops per mL and suit routine adult fluids. Microdrip sets give 60 drops per mL and suit small, slow volumes. Nursing texts such as Open RN's Nursing Skills, chapter 5.14 teach this formula and round the answer to a whole drop, since you cannot count part of one.
A pump needs mL per hour instead: the volume divided by the hours. For a weight-based order the pump rate comes from the dose, the weight and the bag's strength:
Here d is the dose in mcg/kg/min, w the weight in kg and c the concentration in mcg/mL. The 60 turns minutes into hours. The concentration is the drug in milligrams times 1,000, divided by the bag volume in mL. The "Drop count" mode runs the first formula backwards: from the drops you counted, it finds the mL/h and how long the bag will last.
Worked examples
A liter of saline over 8 hours
The order is 1,000 mL over 8 hours, and the tubing says 20 gtt/mL. That is 1,000 × 20 ÷ 480 = 41.7, so you set the clamp to 42 drops a minute, about 10 every 15 seconds. On a pump it would be 125 mL/h. Counting a whole 42 drops gives 126 mL/h, so the bag ends in 7 hours 56 minutes rather than 8 hours.
An antibiotic over 30 minutes
A 100 mL bag runs over 30 minutes on 15 gtt/mL tubing: 100 × 15 ÷ 30 = 50 drops a minute. As a pump rate that is 200 mL/h, because 100 mL in half an hour is twice 100 mL in an hour.
A drip already running
You count 28 drops in a minute on 15 gtt/mL tubing, with 500 mL left. That is 28 × 60 ÷ 15 = 112 mL/h, and the bag lasts about 4 hours 28 minutes. If the order was 125 mL/h, the drip is running slow.
In "Dose" mode, dopamine at 5 mcg/kg/min for a 70 kg adult, from 400 mg in 250 mL (1,600 mcg/mL), needs 13.1 mL/h, and the bag lasts about 19 hours 3 minutes.
Reading your result
The big number is what you count. Count for a full minute when you set the clamp, or for 15 seconds and multiply by 4 for a quick check. Flow from a gravity set drifts as the bag empties and as the patient moves, so recount after a few minutes and at each check.
The drop factor changes the count a lot. The same 1,000 mL over 8 hours is 21 drops a minute on 10 gtt/mL tubing and 125 on microdrip tubing. With microdrip, drops a minute and mL/h are the same number, which makes it an easy check.
Drops a minute for common pump rates
Each count is the pump rate times the drop factor, divided by 60, then rounded to a whole drop.
| mL/h | 10 gtt/mL | 15 gtt/mL | 20 gtt/mL | 60 gtt/mL |
|---|---|---|---|---|
| 50 | 8 | 13 | 17 | 50 |
| 75 | 13 | 19 | 25 | 75 |
| 100 | 17 | 25 | 33 | 100 |
| 125 | 21 | 31 | 42 | 125 |
| 150 | 25 | 38 | 50 | 150 |
| 200 | 33 | 50 | 67 | 200 |
The time strip shows what should be left at each mark, so you can see at a glance whether the bag is ahead of or behind schedule.
Common mistakes
- Dividing by hours instead of minutes. 1,000 × 20 ÷ 8 gives 2,500, sixty times too fast. The drop formula always needs minutes.
- Using the wrong drop factor. Read it off the tubing package in your hand. A 10 gtt/mL set run at a 20 gtt/mL count delivers twice the volume.
- Mixing mg and mcg. Concentration in mg/mL is a thousand times smaller than in mcg/mL. Write the units at every step and check they cancel to mL/h.
- Using pounds as kilograms. A 154 lb patient is about 70 kg. Typing 154 into a kilogram dose more than doubles the rate; switch the weight to lb instead.
- Treating a calculator as the order. The ISMP high-alert list includes IV insulin, heparin, opioids and vasopressors. For these, follow the pump's drug library and your independent double check.
Questions people ask
Sources
- Institute for Safe Medication Practices, ISMP Guidelines for Optimizing Safe Implementation and Use of Smart Infusion Pumps (2020)
- Institute for Safe Medication Practices, High-Alert Medications in Acute Care Settings
- Standard dosage calculation formulas as taught in nursing pharmacology (for example Pickar, Dosage Calculations)
- Ernstmeyer, K. and Christman, E. (eds.), Nursing Skills, Open RN, chapter 5.14: IV Infusion by Gravity