SciencePhysics

Decibel
calculator.

A decibel is a ratio on a log scale, so adding or comparing levels takes some care.

How it's worked out

A level in decibels compares a quantity with a reference. NIST sets out two kinds. A power quantity, such as watts or sound intensity, uses 10 times the logarithm of the ratio.

L\displaystyle L=10log10⁡PP0\displaystyle {}= 10 \log_{10} \frac{P}{P_0}

A field quantity, such as volts or sound pressure, uses 20 times the logarithm, because power goes with the square of the amplitude. A ratio of 100 is 20 dB for power and 40 dB for voltage. NIST also says you must always give the reference level, so a sound level is written against 20 µPa.

L\displaystyle L=20log10⁡FF0\displaystyle {}= 20 \log_{10} \frac{F}{F_0}

Separate sources do not add as plain numbers. Turn each level back into power, add those, and take the logarithm again. OSHA says it directly: it is not correct to sum sound values by arithmetic addition.

L\displaystyle L=10log10⁡∑i10Li/10\displaystyle {}= 10 \log_{10} \sum_i 10^{L_i / 10}

For a small source in open air, the OSHA Technical Manual says the level falls 6 dB each time you double the distance. It gives 90 dB at 1 m, 84 dB at 2 m and 78 dB at 4 m.

L2\displaystyle L_2=L1−20log10⁡r2r1\displaystyle {}= L_1 - 20 \log_{10} \frac{r_2}{r_1}

Worked examples

Sam adds up the machines in a small workshop

Sam has two machines at 80 dB and one at 75 dB. Together they make 83.65 dB, only 3.65 dB above the loudest. The 75 dB machine carries just 13.7% of the power.

If those are A-weighted levels and Sam works 8 hours beside them, that is a dose of 73.2% by the NIOSH rule and 41.5% by the OSHA rule. The levels sit under both limits, so the two doses are under 100%.

Open this example in the tool

Gia checks a speaker from the back of a field

A speaker makes 110 dB at 1 m, and Gia stands 20 m away in open ground. The level there is about 83.98 dB. To reach 85 dB she would have to go back to about 17.8 m.

Both figures assume a single small source and no reflections. A hall, a stage roof or a row of speakers keeps the level higher than this.

Open this example in the tool

Ben adds up gain and loss along a signal chain

Ben's amplifier adds 20 dB and a long cable loses 3 dB. Stages in a chain multiply as ratios, so their decibels add, and the signal comes out 17 dB stronger. That is a power ratio of about 50.1.

Adding works here because one signal passes through each stage in turn. Adding sound sources is a different job, since each one puts in power of its own.

Open this example in the tool

Reading your result

Small rises hide big changes. Two equal sources make 83.01 dB from 80 dB. OpenStax puts twice the intensity at about 3 dB. Ten equal 70 dB sources reach 80 dB, and a 90 dB source beside an 80 dB one gives 90.41 dB, so the quieter one hardly shows.

Loudness is not power. A Wiley physics text reports that 10 dB more seems about twice as loud, though it is ten times the intensity. OpenStax adds that the ear can tell about 1 dB apart at a given frequency, and that 3 dB is easily noticed. Your ear is most sensitive from 2,000 to 5,000 Hz.

How long is too long. NIOSH recommends 85 dBA averaged over 8 hours and halves the time for each 3 dBA more. OSHA allows 90 dBA for 8 hours and halves the time for each 5 dBA, and it starts a hearing conservation program at an 85 dBA average. Impact noise should not pass 140 dB peak. The limits table lists both.

A rough ear check. NIOSH says sounds at 85 dBA often make you raise your voice to reach someone 3 feet away. Around 95 dBA, you likely have to shout.

Common mistakes

  • Adding levels as plain numbers. Two 80 dB machines do not make 160 dB. Use the add levels mode, which works on power.
  • Using 10 where 20 belongs. A gain worked out from volts or sound pressure needs 20. A ratio of 2 is about 3 dB for watts and about 6 dB for volts.
  • Reading any dB figure as dBA. The limits use A-weighted levels, which cut the response to very low frequencies. An unweighted figure can sit above the A-weighted one for the same noise.
  • Using the 6 dB rule indoors. OSHA gives that drop for a free field, with no walls. Reflections in a room keep the level higher, so a real room falls more slowly.
  • Reading 0 dB as silence. On the sound scale, 0 dB is the reference, near the threshold of hearing at 1,000 Hz. A negative level is still a real quantity.

Questions people ask

Power goes with the square of voltage, and a logarithm turns that square into a factor of 2 out front. So 10 times the log of a squared ratio equals 20 times the log of the ratio. When you are unsure, go back to the power form and work from there.

Sources